Tap Water Results

Huntsville Utilities Water Dept. water quality

Huntsville, AL · serves 310,107 people (103,369 connections) · Surface water · Local government · EPA ID AL0000882

Data: U.S. EPA · How we read the data · How we check it

Buys water from Limestone County Water & Sewer Authority. Treated water bought from another system can carry that system's contaminants.

Summary

PFAS above the 2024 federal limits. Systems have until 2029 to meet the PFAS limits.

Is it an emergency? No: PFAS limits are about years of exposure, not a glass of water, and nothing in EPA's data calls for you to stop drinking the water today. If your utility ever issues a boil-water or do-not-drink notice, follow it.

PFAS
Above limitPFOS above the federal limit in EPA's 2023–2025 testing (PFOS 7.7 ppt vs a limit of 4 ppt, where ppt = parts per trillion).
Lead
Below action level0 ppb (parts per billion) at the 90th percentile: 9 in 10 homes sampled were at or below it. Action level 15 ppb, falling to 10 ppb in Nov 2027. Monitoring period Jan 2024 – now, still in progress (results reported so far). Your home's pipes can make yours higher.
Violations
None health-basedNo health-based violations since 2016.
What you can do

PFAS (“forever chemicals”)

EPA UCMR 5: 5 entry points tested Feb 2023 to Dec 2023. "Average" is the highest entry-point average (non-detects counted as zero), the way EPA compares UCMR 5 results to the limits. ppt = parts per trillion. These results do not determine compliance.

ContaminantHighest averageHighest resultLimitStatus
PFOA
One sample above limit
Limit 4 ppt
2.35 ppt
59% of the limit
4.7 ppt4 pptOne sample above limit
PFOS
Above limit
Limit 4 ppt
7.7 ppt
1.93× the limit
9 ppt4 pptAbove limit
PFHxS
Not detected
Limit 10 ppt
––10 pptNot detected
PFNA
Not detected
Limit 10 ppt
––10 pptNot detected
HFPO-DA (GenX)
Not detected
Limit 10 ppt
––10 pptNot detected
Hazard Index (a combined score for PFHxS, PFNA, GenX and PFBS, where above 1 is over the limit)
Detected, below limit
Limit 1
0.00290.00311Detected, below limit
PFBS
Detected, below limit
Guideline 2,000 ppt
5.9 ppt6.2 ppt2,000 ppt guidelineDetected, below limit
PFBA
Detected, below limit
Guideline 6,000 ppt
10.3 ppt11 ppt6,000 ppt guidelineDetected, below limit
PFHxA
Detected, below limit
Guideline 3,000 ppt
4.25 ppt4.4 ppt3,000 ppt guidelineDetected, below limit
PFPeA
Detected, no limit
4.8 ppt5.3 pptnoneDetected, no limit

For context: the PFOS average is higher than at 88% of the Alabama systems EPA tested.

29 PFAS tested, 6 detected at least once. "Not detected" means below EPA's reporting limit (about 2 to 20 ppt depending on the chemical), not proven zero. PFAS not listed were not detected. The limits for PFHxS, PFNA, GenX and the Hazard Index were proposed for rescission in May 2026. That proposal is not final. Systems have until 2029 to meet the limits.

Lithium

Not detected in 16 samples (reporting limit 9 ppb). About lithium.

Lead and copper

Latest 90th percentile: 0 ppb lead (Jan 2024 – now (in progress)). Below action level

Highest since 2016: 5 ppb (Jun 2018).

Monitoring periodLead (90th pct.)
Jan 2024 – now (in progress)0 ppb
Jan 2021 – Dec 20231 ppb
Jan 2020 – Dec 20200 ppb
Earlier results (9)
Jan 2019 – Dec 20190 ppb
Jul 2018 – Dec 20180 ppb
Jan 2018 – Jun 20185 ppb
Jan 2013 – Dec 20155 ppb
Jan 2010 – Dec 20125 ppb
Jan 2007 – Dec 20095 ppb
Jan 2006 – Dec 20065 ppb
Jan 2005 – Dec 20054 ppb
Jan 2004 – Dec 20040 ppb

Lead comes from pipes and fixtures, not the source water, so it varies home to home. The 90th percentile means 9 in 10 sampled homes were at or below it. More on lead.

Violations

0
Health-based since 2016
1
Monitoring/reporting since 2016
0
Health-based unresolved now
1
Total ever recorded, incl. paperwork

Health-based violations mean a contaminant exceeded a limit or a required treatment step was missed. Monitoring and reporting violations mean required tests or reports were late or missing, so the water's quality during that time is unknown. The total includes every violation in EPA's records, most of them paperwork.

Earlier EPA testing (2013–2020)

ContaminantHighestGuidelineDetectedTested
Manganese12.5 ppb300 ppb12 of 14UCMR 4 (2019)
Vanadium0.7 ppb21 ppb14 of 20UCMR 3 (2015)
Chromium-60.71 ppb–20 of 20UCMR 3 (2015)
1,4-Dioxane0.21 ppb0.35 ppb7 of 10UCMR 3 (2015)
Strontium0.15 ppm1.5 ppm20 of 20UCMR 3 (2015)
Chlorate380 ppb210 ppb20 of 20UCMR 3 (2015)
Molybdenum1.1 ppb40 ppb2 of 20UCMR 3 (2015)

Where it serves

Huntsville

ZIP codes the system reported serving: 35801, 35802, 35803, 35804, 35805, 35806, 35807, 35809, 35810, 35811, 35812, 35813, 35814, 35815, 35816, 35824, 35893, 35894, 35895, 35896, 35897, 35899

Nearby utilities

Questions

Is Huntsville Utilities Water Dept. water safe to drink?

Huntsville Utilities Water Dept. has no health-based violations since 2016. EPA testing found PFAS above the 2024 federal limits, which systems must meet by 2029. Federal data can't tell you about your own pipes: lead comes from service lines and plumbing, so test your tap if your home was built before 1986. For the official word, read the utility's annual Consumer Confidence Report.

Does Huntsville Utilities Water Dept. water have PFAS?

Yes. EPA's 2023–2025 testing of Huntsville Utilities Water Dept. found 6 PFAS at least once. The highest entry-point averages were above the federal limit for PFOS: PFOS 7.7 ppt (limit 4 ppt for PFOA and PFOS, 10 ppt for the others).

What is the lead level in Huntsville Utilities Water Dept. water?

The most recent 90th-percentile lead result for Huntsville Utilities Water Dept. is 0 ppb, for the monitoring period that began Jan 2024 (still in progress). The federal action level is 15 ppb, falling to 10 ppb in November 2027. The 90th percentile means 9 in 10 homes sampled were at or below this number. Individual homes can be higher.

Check these numbers yourself

Every figure on this page comes from public EPA records. You don't have to take our word for it:

Found something that doesn't match? Tell us and we'll check it against EPA's records. How we check our data.

Source: U.S. EPA drinking water records and PFAS testing (UCMR 5). How we read the data.