Seminole County Southeast water quality
Sanford, FL · serves 70,040 people (18,535 connections) · Groundwater · Local government · EPA ID FL3590571
Data: U.S. EPA · How we read the data · How we check it
Buys water from City of Casselberry. Treated water bought from another system can carry that system's contaminants.
Summary
No federal limits exceeded in EPA data.
- PFAS
- Not detectedNone of 29 PFAS found above EPA's reporting limits in 4 samples (2023–2025).
- Lead
- Below action level1.2 ppb (parts per billion) at the 90th percentile: 9 in 10 homes sampled were at or below it. Action level 15 ppb, falling to 10 ppb in Nov 2027. Monitoring period ending Dec 2023. Your home's pipes can make yours higher.
- Violations
- None health-basedNo health-based violations since 2016.
- Built before 1986, or not sure what your service line is made of? Check your service line and test your tap. Utility data can't show your pipes.
- Tested your own tap? Compare your result with these numbers. Moving? Compare this system with another.
- Read Seminole County Southeast's annual water quality report (Consumer Confidence Report). It lists every regulated contaminant tested and is usually on the utility's website or mailed with your bill, and you can also request it at (407) 665-2759. EPA: how to find it.
PFAS (“forever chemicals”)
EPA UCMR 5: 2 entry points tested Nov 2024 to May 2025. "Average" is the highest entry-point average (non-detects counted as zero), the way EPA compares UCMR 5 results to the limits. ppt = parts per trillion. These results do not determine compliance.
| Contaminant | Highest average |
|---|---|
| PFOA Not detected Limit 4 ppt | – |
| PFOS Not detected Limit 4 ppt | – |
| PFHxS Not detected Limit 10 ppt | – |
| PFNA Not detected Limit 10 ppt | – |
| HFPO-DA (GenX) Not detected Limit 10 ppt | – |
| Hazard Index (a combined score for PFHxS, PFNA, GenX and PFBS, where above 1 is over the limit) Not detected Limit 1 | – |
| PFBS Not detected Guideline 2,000 ppt | – |
| PFBA Not detected Guideline 6,000 ppt | – |
| PFHxA Not detected Guideline 3,000 ppt | – |
29 PFAS tested, 0 detected at least once. "Not detected" means below EPA's reporting limit (about 2 to 20 ppt depending on the chemical), not proven zero. PFAS not listed were not detected. The limits for PFHxS, PFNA, GenX and the Hazard Index were proposed for rescission in May 2026. That proposal is not final. Systems have until 2029 to meet the limits.
Lithium
Not detected in 4 samples (reporting limit 9 ppb). About lithium.
Lead and copper
Latest 90th percentile: 1.2 ppb lead (Jan 2023 – Dec 2023). Below action level
Highest since 2016: 5.4 ppb (Dec 2017).
| Monitoring period | Lead (90th pct.) |
|---|---|
| Jan 2023 – Dec 2023 | 1.2 ppb |
| Jan 2020 – Dec 2020 | 1.5 ppb |
| Jan 2017 – Dec 2017 | 5.4 ppb |
Earlier results (9)
| Jan 2014 – Dec 2014 | 0 ppb |
| Jan 2011 – Dec 2011 | 3.1 ppb |
| Jan 2009 – Dec 2009 | 4.5 ppb |
| Jan 2006 – Dec 2006 | 2.7 ppb |
| Jan 2003 – Dec 2003 | 1.8 ppb |
| Jan 2000 – Dec 2000 | 4.76 ppb |
| Jan 1999 – Dec 1999 | 4 ppb |
| Jan 1998 – Jun 1998 | 1 ppb |
| Jul 1997 – Dec 1997 | 3 ppb |
Lead comes from pipes and fixtures, not the source water, so it varies home to home. The 90th percentile means 9 in 10 sampled homes were at or below it. More on lead.
Violations
Health-based violations mean a contaminant exceeded a limit or a required treatment step was missed. Monitoring and reporting violations mean required tests or reports were late or missing, so the water's quality during that time is unknown. The total includes every violation in EPA's records, most of them paperwork.
Earlier EPA testing (2013–2020)
| Contaminant | Highest | Guideline |
|---|---|---|
| Manganese | 35.9 ppb | 300 ppb |
| Molybdenum | 3.26 ppb | 40 ppb |
| Strontium | 0.14 ppm | 1.5 ppm |
| Vanadium | 0.3 ppb | 21 ppb |
| Chlorate | 620 ppb | 210 ppb |
| Chromium-6 | 0.13 ppb | – |
Where it serves
Sanford, Oviedo, Winter Springs, Altamonte Springs, Casselberry, Maitland, Fern Park
ZIP codes the system reported serving: 32701, 32707, 32708, 32730, 32751, 32765, 32771, 32792
Nearby utilities
- City of Sanford Sanford · same area
- City of Winter Springs Winter Springs · 7 mi · PFAS above limit
- Deltona Water Deltona · 9 mi · PFAS above limit
- Volusia County – Enterprise Deltona · 9 mi · PFAS above limit
- City of Casselberry Casselberry · 9 mi
- Orange City Utilities Orange City · 10 mi · PFAS above limit
Questions
Is Seminole County Southeast water safe to drink?
Seminole County Southeast has no health-based violations since 2016. EPA testing found no PFAS above the federal limits. Federal data can't tell you about your own pipes: lead comes from service lines and plumbing, so test your tap if your home was built before 1986. For the official word, read the utility's annual Consumer Confidence Report.
Does Seminole County Southeast water have PFAS?
EPA tested Seminole County Southeast for 29 PFAS between Nov 2024 and May 2025 and none were detected above the reporting limits (about 2 to 20 ppt depending on the chemical).
What is the lead level in Seminole County Southeast water?
The most recent 90th-percentile lead result for Seminole County Southeast is 1.2 ppb, for the period ending Dec 2023. The federal action level is 15 ppb, falling to 10 ppb in November 2027. The 90th percentile means 9 in 10 homes sampled were at or below this number. Individual homes can be higher.
Check these numbers yourself
Every figure on this page comes from public EPA records. You don't have to take our word for it:
- EPA's own report for FL3590571: violations, enforcement and inspections, straight from EPA.
- EPA UCMR 5 data: the PFAS and lithium results (search the file for PWSID FL3590571).
- EPA SDWIS download: the lead results, population and violation records we use.
- The utility's annual water quality report (Consumer Confidence Report): ask Seminole County Southeast at (407) 665-2759, or see EPA's guide to finding it.
Found something that doesn't match? Tell us and we'll check it against EPA's records. How we check our data.
Source: U.S. EPA drinking water records and PFAS testing (UCMR 5). How we read the data.